LAT Calibration Center No. 00121

ACCREDIA-accredited calibration of balances up to 1000 kg and of micro-dispensers from 0.1 µL to 200 mL.

ACCREDIA-accredited calibration center

Gibertini Elettronica is accredited by ACCREDIA as LAT calibration center No. 00121, in accordance with UNI CEI EN ISO/IEC 17025, for the calibration of weighing instruments (balances, NAWI) and of micro-dispensers (POVA): pipettes, syringes, dispensers, diluters and burettes.

  • Accreditation number: LAT No. 00121
  • Reference standard: UNI CEI EN ISO/IEC 17025
  • Accredited instruments: balances (NAWI) and micro-dispensers (POVA): pipettes, syringes, dispensers, diluters and burettes
  • Accredited: balances since 1997, micro-dispensers since 2002 (originally by SIT, now ACCREDIA)
  • Instrument brand: any

The accredited measurement ranges, locations and calibration uncertainties can be consulted in the official schedule published by ACCREDIA, in the laboratory record, and in summary in the in-depth article on accredited calibration.

ACCREDIA Calibration mark for accredited calibration center LAT No. 00121

Accredited center since 1997

LAT No. 00121

1000 kgbalances, at the customer's site
0.1 µL – 200 mLmicro-dispensers, in the Novate Milanese laboratory

The mark appears on the calibration certificates issued by the center.

Open the record on ACCREDIA

Accredited calibration of balances

Balances up to 1000 kg, calibrated at the customer's site.

Balances

Non-automatic weighing instruments

up to 1000 kg
Analytical balances
Precision technical balances
Bench scales
Platform scales
Industrial platforms
Load cells
  • Minimum weight according to the EURAMET cg-18 guide on request
  • Statement of conformity to the customer's requirements on request
  • Checks according to Ph. Eur. 2.1.7, GMP and GLP on request, not accredited
View the certificate contents

The LAT calibration certificate for balances

Official document with the ACCREDIA mark, issued by LAT center No. 00121.

ACCREDIA mark of LAT center No. 00121
BalancesCertificate contents
LAT No. 00121

Identification and traceability

  • Identification of the instrument, the customer and the calibration activity
  • Certificate number and signature of the laboratory technical manager
  • Traceability chain of the center and calibration procedure applied
  • Technical data of the instrument and configuration parameters
  • Date, location and ambient conditions of the calibration

Tests and results

  • Repeatability test, expressed as the standard deviation of the readings
  • Eccentricity test
  • Linearity test, with the indication errors
  • Expanded global uncertainty, with k = 2 and a confidence level of approximately 95 %
  • Table of the expanded global uncertainty as a function of load

On request

In the same certificate

  • Minimum weight according to the EURAMET cg-18 guide, with values as a function of the safety factor and of the accuracy level required by the process
  • Statement of conformity to the customer's requirements, according to ISO/IEC 17025 and the ILAC-G8 guide, on the repeatability, eccentricity and linearity tests, with the decision rule agreed at contract stage
  • Checks according to Ph. Eur. 2.1.7, GMP and GLP, not accredited

The decision rule establishes how measurement uncertainty is taken into account in the statement of conformity. The tolerance limit comes from a standard or from the customer's process requirements.

Example

Global uncertainty and minimum weight in the certificate

Table of the expanded global uncertainty as a function of load

The certificate gives the expanded global uncertainty as a linear equation of the load R, with k = 2, and the table of values by percentage of load.

Ugl(W) = 8.70 · 10−5 g + 3.03 · 10−6 · R
LoadRUgl(W)Ugl(W) / R
0 %0 g0.000087 g—
10 %6 g0.000105 g0.0018 %
25 %15 g0.000132 g0.0009 %
50 %30 g0.000178 g0.0006 %
75 %45 g0.000223 g0.0005 %
100 %60 g0.000269 g0.0004 %

Minimum weight according to the EURAMET cg-18 guide

Minimum weight as a function of the accuracy required by the process and of the safety factor SF, calculated from the same global uncertainty.

Required accuracySF = 1SF = 2SF = 3
0.1 %87.3 mg175.1 mg263.4 mg
0.5 %17.4 mg34.8 mg52.3 mg
1.0 %8.7 mg17.4 mg26.1 mg
1 mg10 mg0.1 g1 g10 g100 g10 %1 %0.1 %0.01 %0.001 %0.0001 % minimum weight 8.7 mg requirement 1 % outside requirement safe weighing range

Values calculated from the example in the Gibertini application note on minimum weight: laboratory balance with 60 g capacity and 0.00001 g readability. Each balance has its own global uncertainty and its own minimum weight, stated in its certificate.

In-depth documents

Accredited calibration of micro-dispensers

Micro-dispensers from 0.1 µL to 200 mL, calibrated in the Novate Milanese laboratory.

Micro-dispensers

Single-channel and multichannel, fixed or variable volume

0.1 µL – 200 mL
PipettesISO 8655-2
SyringesISO 8655-9
DispensersISO 8655-5 · from 1 µL to 200 mL
DilutersISO 8655-4 · sample uptake from 5 µL to 1 mL, delivery from 50 µL to 100 mL
BurettesISO 8655-3 · up to 100 mL
  • Calibration procedures compliant with ISO 8655-6:2022
  • Statement of conformity to ISO 8655-2, -3, -4, -5 and -9, according to the type of instrument
  • Test volumes: the nominal volume on fixed-volume instruments, at least three volumes on adjustable-volume instruments; on multichannel instruments, every channel
  • Statement of conformity to the customer's requirements on request
  • Checks according to GMP and GLP on request, not accredited
  • Delivery within 15 days of receipt of the order

Decontamination form. Pipettes, syringes, dispensers, diluters and burettes sent to the laboratory must be accompanied by the completed decontamination form. Download the decontamination form (PDF, in Italian)

What changes in ISO 8655-6:2022

The LAT calibration certificate for micro-dispensers

Official document with the ACCREDIA mark, issued by LAT center No. 00121.

For each volume calibrated, the certificate gives the systematic error and the random error, determined gravimetrically according to ISO 8655-6, with the associated uncertainty, and the statement of conformity to the maximum permissible errors of the part of ISO 8655 applicable to the type of instrument.

ACCREDIA mark of LAT center No. 00121
Micro-dispensersCertificate contents
LAT No. 00121

Identification and traceability

  • Identification of the instrument, the customer and the calibration activity
  • Certificate number and signature of the laboratory technical manager
  • Traceability chain of the center and calibration procedure applied
  • Technical data of the instrument and configuration parameters
  • Date, location and ambient conditions of the calibration: water and ambient temperature, relative humidity, atmospheric pressure

Tests and results

  • Gravimetric tests according to ISO 8655-6: at the nominal volume on fixed-volume instruments, at at least three volumes on adjustable-volume instruments and, on multichannel instruments, on every channel
  • Systematic error and random error (standard deviation and coefficient of variation) for each volume calibrated
  • Expanded global uncertainty, with a coverage factor corresponding to a confidence level of approximately 95 %
  • Statement of conformity to ISO 8655-2, -3, -4, -5 and -9, according to the type of instrument

On request

Statements and checks

  • Statement of conformity to the customer's requirements
  • Checks according to GMP and GLP, not accredited

Chapter 2.1.7 of the European Pharmacopoeia covers only balances for analytical use; for micro-dispensers, the checks on request refer to the customer's GMP and GLP requirements. The parts of ISO 8655 cited in the statement of conformity are described below.

ISO8655-2

Pipettes

Air-displacement (type A) and positive-displacement (type D) pipettes, single-channel and multichannel, with tips: metrological requirements, maximum permissible errors, marking and information for the user.

ISO8655-3

Burettes

Burettes up to 100 mL nominal volume: metrological requirements, maximum permissible errors, marking and information for the user.

ISO8655-4

Diluters

Diluters with a sample uptake capacity from 5 µL to 1 mL and a diluent delivery capacity from 50 µL to 100 mL: metrological requirements, maximum permissible errors, marking and information for the user.

ISO8655-5

Dispensers

Dispensers with nominal volume from 1 µL to 200 mL: metrological requirements, maximum permissible errors, marking and information for the user.

ISO8655-9

Syringes

Manually operated precision laboratory syringes, in glass or glass and metal, for liquids and gases: metrological requirements, maximum permissible errors, marking and information for the user.

ISO8655-6

Measurement procedure

Gravimetric reference method for determining volume, applied by the center in calibration.

ISO 8655 series, «Piston-operated volumetric apparatus», 2022 edition. Sources: ISO and national standards bodies.

Metrological traceability

The LAT calibration certificate documents the link between the calibrated instrument and the national and international measurement standards. The traceability chain is the unbroken sequence of documented calibrations that connects the working standard used in the measurement to the primary standards, through certificates that are themselves traceable.

The center's calibration methods, the EURAMET cg-18 guide for balances and ISO 8655-6:2022 for micro-dispensers, are those in the ACCREDIA accreditation schedule. The uncertainty given in the certificate is the expanded uncertainty with a coverage factor corresponding to a confidence level of approximately 95 %; for balances the coverage factor is k = 2 and the uncertainty is determined according to the EURAMET cg-18 guide.

Accreditation attests to the technical competence, independence and impartiality of the laboratory. In Italy, ACCREDIA is the sole national accreditation body appointed by the Government under Regulation (EC) No. 765/2008.

ACCREDIA is a member of EA, IAF and ILAC. For calibration it is a signatory of the EA MLA and ILAC MRA mutual recognition arrangements: certificates issued under its mark are recognized as equivalent by the accreditation bodies of the other signatory countries.

The calibration certificate is part of the quality management system documentation and may be requested during an inspection or audit.

The ISO calibration report is a separate service, without the ACCREDIA mark, performed by the technical service department on balances, platforms and silos up to 20 t and on other instruments.

Request for accredited calibration

LAT laboratory No. 00121 performs accredited calibrations of balances at the customer's site and of micro-dispensers in the Novate Milanese laboratory.

Request a quote View service and ISO calibration